Indoor 2500A Red Copper Silver Plated Contacts For Switchgear 55X82 Mm

Brand Name : QIUPU

Model Number : 55X82mm

Certification : ISO

Place of Origin : WENZHOU

MOQ : 60 PCS

Payment Terms : T/T, Western Union

Supply Ability : 50000 PCS/Month

Delivery Time : 4 Days

Packaging Details : Cartons

Material : Red Copper

Current : 2500A

Dia : 55mm

Length : 82mm

plate : silver

Thickness : 3 uM

Contact Now

2500A Red Copper Fix Contact 55X82 With Indoor Vacuum Circuit Breaker

So the ring net cabinet is not only used as the contact switch cabinet, but also as the loop in and out of the switch cabinet, measuring cabinet, PT cabinet. Loop-in and loop-out switchgear not only can load switch-fuse combination, but also can load circuit breaker, such as domestic HXGN, Schneider SF6, Siemens 8DH, and second protection can install microcomputer protection device. But the ring net cabinet breaker has the load limit, each factory's ring net cabinet limits are different. If Schneider RM6 ring net cabinet, Transformer high voltage switch protection is greater than 2000 KVA capacity, must adopt circuit breaker + VIP 300 microcomputer protection. However, the load of the in-and-out line of the cabinet is not limited(except the larger load is 1 meter wide).

As mentioned above, the function of the ring cabinet is simple, it is to connect different power parts, generally do not use it to realize the control, protection and measurement of specific electrical equipment; If you really need these things, it must be you choose the wrong, should choose the cabinet; Where there is high pressure, high pressure measurement should be given priority over low pressure measurement; When there is no way to measure it, low pressure measurement is considered. At this point, the low voltage measuring cabinet should be placed in the front of the low voltage entry line, behind the transformer, from the surface, it is not under the protection of Jilianggui, but in general, it should be in the transformer.

Indoor 2500A Red Copper Silver Plated Contacts For Switchgear 55X82 Mm


Product Tags:

silver plating electrical contacts

      

tulip contacts

      
Quality Indoor 2500A Red Copper Silver Plated Contacts For Switchgear 55X82 Mm for sale